1000 LPH Industrial RO System | 1 m³/h RO Plant

The 1000 LPH Industrial RO System is designed to produce up to 1,000 liters of purified water per hour for commercial and industrial water treatment applications. Pretreatment, RO configuration, materials and control options can be selected according to feed water quality and project requirements.

Technical Specifications

  • Feed Water: Tap water, well water, groundwater or suitably pretreated reclaimed water
  • Inlet Pressure: 0.2–0.3 MPa
  • Operating Pressure: 0.3–1.5 MPa, depending on feed water conditions
  • Nominal Product Water Capacity: 1,000 L/h (1 m³/h)
  • Salt Rejection: Up to or above 99%, depending on membrane selection and operating conditions
  • Product Water Conductivity: Depends on feed water quality and system configuration; lower conductivity targets may require double-pass RO or additional polishing
  • Control Options: Automatic or semi-automatic operation
  • Material Options: PVC,

1000 LPH Industrial RO System Features

Efficient Operation and Optimized Water Recovery

The 1000 LPH industrial RO system uses reverse osmosis membrane technology to remove dissolved salts and other impurities from feed water. System recovery is determined by feed water quality, membrane selection and operating conditions. Proper pretreatment and system design help maintain stable performance and optimize operating costs.

Easy Installation and Maintenance

The system can be supplied as a skid-mounted unit with integrated pumps, RO membranes, piping and control components. Installation requires appropriate feed water connections, drainage, electrical supply and commissioning. The compact arrangement allows convenient access for routine inspection and maintenance.

Flexible RO Configurations

Single-pass or double-pass RO configurations can be selected according to feed water conditions and required product water quality. Pretreatment options may include multimedia filtration, activated carbon filtration, water softening and cartridge filtration. Additional polishing treatment can also be considered for applications requiring lower conductivity.

Automatic Operation and System Protection

Automatic control options are available for monitoring system operation and managing startup and shutdown sequences. Depending on the selected configuration, the system can include tank-level control, low-pressure protection, high-pressure protection and automatic flushing functions.

Clear and Practical Control Interface

The control panel can be configured to display operating status and key parameters such as pressure and product water conductivity. Control functions and instrumentation can be customized according to project requirements.

Compact Skid-Mounted Design

The 1000 LPH RO system can be arranged on a compact skid to simplify transportation, installation and maintenance. Equipment dimensions, component layout and material selection can be adapted to the available installation space and project specifications.

1000 LPH Industrial RO System Video

1000 LPH Industrial RO System Components & Functions

Main Components of a 1000 LPH Reverse Osmosis System

Quartz Sand Filter

Reduces suspended solids, sediment, rust and turbidity in the feed water. Backwashing can be performed manually or automatically, depending on the selected valve and control configuration.

Resin Softening Filter

Reduces calcium and magnesium hardness through ion exchange, helping to control scaling in the RO membrane system. Softening requirements depend on feed water hardness and system design.

Reverse Osmosis Membrane System

Removes a high proportion of dissolved salts and other contaminants through membrane separation. Salt rejection and product water quality depend on membrane selection, feed water composition and operating conditions.

Pressure Gauge

Displays pressure at designated monitoring points, helping operators assess feed water pressure, RO operating pressure and pressure changes across system components.

Electrical Control Section

Provides electrical control and protection functions for the RO system. Control voltage, electrical components and automation features can be selected according to the equipment configuration and project requirements.

Conductivity Monitoring

Monitors product water conductivity to help operators evaluate RO performance. Alarm and control functions can be configured according to the required water quality limits.

1000 LPH industrial RO system with FRP pretreatment tanks and stainless steel membrane housings
1000 LPH reverse osmosis water treatment system with control cabinet and pretreatment filters
Industrial 1000 LPH RO water purification equipment with stainless steel membrane housings
1000 LPH industrial reverse osmosis system electrical control panel

1000 LPH Industrial RO System Applications

The 1000 LPH Industrial RO System is suitable for commercial and industrial applications requiring approximately 1,000 liters of purified water per hour. The system can be configured according to feed water quality, required product water standards and operating conditions.

Typical Applications:

  • Industrial Process Water: Purified water supply for manufacturing processes and industrial equipment.

  • Commercial Water Purification: Water treatment for hotels, schools, commercial facilities and centralized water supply systems.

  • Well Water Treatment: Reverse osmosis treatment of groundwater and well water after appropriate pretreatment.

  • Food and Beverage Processing: Water purification for selected production processes, subject to applicable water quality and hygiene requirements.

  • Laboratory and Pharmaceutical Water Pretreatment: RO pretreatment for systems requiring additional purification stages such as EDI or polishing units.

For applications with specific conductivity, microbial or regulatory requirements, the treatment process should be designed based on feed water analysis and the required final water quality.

1000 LPH Industrial RO System FAQ

Can the 1000 LPH industrial RO system be customized?

Yes. The 1000 LPH RO system can be configured according to feed water quality, required product water quality, local voltage and frequency, and installation conditions. Options include pretreatment, membrane configuration, control functions and construction materials.

The suitable feed water TDS depends on the selected RO membranes, operating pressure and system design. Standard brackish water RO configurations are commonly used for tap water and moderately saline groundwater. Higher TDS levels may require different membranes, pumps and operating conditions. A feed water analysis is recommended before final selection.

It may be possible, depending on the feed water conductivity and membrane performance. For more demanding conductivity targets, such as below 5 μS/cm or 2 μS/cm, a double-pass RO configuration or additional polishing treatment may be required. Final water quality should be confirmed through system design and testing.

Feed water consumption depends on the designed recovery rate. For example, at 75% recovery, a system producing 1,000 L/h of purified water requires approximately 1,333 L/h of feed water and discharges approximately 333 L/h of concentrate. Actual recovery depends on feed water quality and operating conditions.

  • Electrical configurations can be selected according to the destination country’s power supply requirements, including voltage, frequency and phase. Please provide the installation site’s electrical specifications when requesting a quotation.

Yes. Clear Environment supports OEM requirements, equipment configuration coordination and sourcing of related water treatment components. We work with distributors, engineering companies and system integrators to arrange suitable equipment and consolidate related products when required.