Seawater RO Membrane
Seawater RO membranes (SWRO membranes) are designed for reverse osmosis desalination systems treating seawater and other high-salinity feedwater. Compared with standard brackish water RO membranes, SWRO elements are developed for higher osmotic pressure conditions and typically operate at higher feed pressures.
Clear Environment supplies 4040 and 8040 seawater reverse osmosis membrane elements for desalination projects, membrane replacement, and water treatment equipment integration. These membranes are used in coastal desalination plants, offshore water treatment systems, and industrial applications requiring freshwater production from high-salinity sources.
Selecting a suitable seawater RO membrane requires consideration of feedwater salinity, operating pressure, temperature, target recovery rate, and required permeate quality. We support engineering companies, system integrators, and distributors with membrane specification comparison, model selection, and sourcing from Chinese manufacturers.

Key Features of Seawater RO Membranes
High Salt Rejection: SWRO membrane elements are designed for high-salinity feedwater desalination. Selected models offer salt rejection rates of up to 99.8% under specified test conditions, depending on the membrane model.
Designed for High-Pressure Operation: Seawater RO membranes are developed for the higher operating pressures required to overcome seawater osmotic pressure. Maximum allowable pressure varies by membrane model and must be checked against the technical datasheet.
Thin-Film Composite Membrane Construction: Polyamide thin-film composite membranes provide selective salt separation. Chemical cleaning must follow the manufacturer’s specified pH, temperature, and chemical compatibility limits.
4040 and 8040 Membrane Options: Available sizes support different system capacities and membrane replacement requirements. Selection should consider membrane dimensions, feedwater salinity, operating conditions, and compatibility with existing pressure vessels.
Available Seawater RO Membrane Models
Clear Environment supplies seawater RO membrane elements for SWRO desalination systems and membrane replacement projects. Available models include 4040 and 8040 configurations with different membrane areas, feed spacer thicknesses, and permeate flow ratings.
The specifications below are based on standard test conditions. Actual membrane performance depends on feedwater salinity, temperature, operating pressure, recovery rate, and system design.

| Model | Effective Membrane Area ft2(m2) | Inlet grid mil(mm) | Permeate Flow GPD(m3/d) | Stable desalination rate% | Minimum desalination rate% |
|---|---|---|---|---|---|
| SW-8040-400HRLE/28 | 400 (37.2) | 28 (0.71) | 7500 (28) | 99.8 | 99.6 |
| SW-4040-82HRLE/28 | 82 (7.6) | 28 (0.71) | 1450 (5.5) | 99.7 | 99.6 |
| SW30HRLE-370/34 | 370 (34.3) | 34 (0.86) | 6700 (25) | 99.7 | 99.6 |
| Note: Individual element flow may vary by ±20%. | |||||
| Test Conditions: 1. Test pressure: 800 psi (5.5 MPa) 2. Test temperature: 25°C 3. Test solution: 32000 ppm NaCl 4. Test solution pH: 7.5 5. Single element recovery rate: 8% | |||||
How to Select Seawater RO Membranes for Different Applications

1. Coastal and Island Desalination Projects
The SW-8040-400HRLE/28 membrane element is an option for seawater desalination plants using 8-inch RO pressure vessels. Its larger membrane area and rated permeate flow make it suitable for evaluation in multi-element, higher-capacity SWRO systems. Final selection should be based on feedwater conditions, system design, and required permeate capacity.
2. Compact Marine and Small-Scale SWRO Systems
The SW-4040-82HRLE/28 model is designed for systems using 4-inch membrane elements. It can be considered for compact marine desalination equipment, small coastal installations, and other applications where system capacity or installation space favors 4040 membranes.
3. High-Salinity Water Treatment and Water Recovery
The SW30HRLE-370/34 model features a 34 mil feed spacer and can be evaluated for high-salinity RO applications where feed-channel conditions require particular attention. Its suitability depends on feedwater composition, pretreatment, operating pressure, and recovery requirements.
OEM & Private Label Service

Custom branding illustration. Actual labeling options depend on order requirements.
Clear Environment supports OEM and private-label sourcing for seawater RO membrane elements, subject to model availability and order quantity.
Custom Labels: Customer branding on membrane elements
Customized Packaging: Neutral or customer-branded cartons
Model Identification: Product model and specification labeling
Technical Support: Membrane specification comparison and replacement selection
Export Coordination: Packaging, order consolidation, and international shipment arrangements
OEM options and minimum order quantities are confirmed according to the selected membrane model and customization requirements.
Seawater RO Membrane Replacement Options
Clear Environment helps water treatment companies and system integrators source seawater RO membrane elements for replacement and retrofit projects.
We can evaluate Chinese-brand SWRO membrane alternatives for selected models from well-known membrane brands, including DuPont, Toray, Hydranautics, LG Chem, and Vontron.
Replacement suitability must be confirmed based on membrane dimensions, operating pressure, feedwater salinity, salt rejection, permeate flow, and compatibility with the existing RO system.
Please provide the original membrane brand, model number, and operating conditions so we can help identify suitable replacement options.
For lower-salinity feedwater applications, explore our Brackish Water RO Membranes and compare available membrane options.
Explore our full RO Membrane product range for additional membrane options.
Related Articles
- Characteristics of Reverse Osmosis Membrane Fouling and Reverse Osmosis Membrane Cleaning Methods
- Prevention of Silica Fouling on RO Membranes
- RO Membrane Antiscalant Dosing: From Calculation Principles to Practical Application
- Besides reverse osmosis membrane flux, what other key design parameters are easily overlooked but can significantly impact membrane life?
- Relationship Between RO Membrane Element Pressure Limits and Recovery Rate in Water Reuse and Zero Liquid Discharge Applications
- How to Choose RO Membranes from China: 3 Key Factors to Consider