Lab Water Purification System
Laboratory RO Water Purification Systems from China
Clear Environment supplies laboratory RO water purification systems for research laboratories, universities, testing facilities, and industrial quality control applications. These systems use reverse osmosis technology to reduce dissolved salts and other impurities in feed water, providing purified water for routine laboratory operations and applications with suitable water quality requirements.
Our product range includes compact benchtop units, floor-standing laboratory water purification systems, and customized configurations for different water consumption requirements. We help laboratory equipment distributors, engineering companies, and end users select suitable systems based on feed water quality, required water purity, production capacity, and installation conditions. Additional purification stages can be considered where higher water quality is required.
Laboratory RO Water Purification System – Feed Water Requirements
Feed Water Requirements
Water Source: Municipal Tap Water
Power Supply: 220V / 50Hz
Silt Density Index (SDI): < 4
Temperature: 5–45°C
Total Dissolved Solids (TDS): < 200 ppm
Pressure Range: 1.5–4 bar
Maximum Conductivity: < 400 μS/cm
Maximum Free Chlorine: < 3 ppm
Turbidity: < 1 NTU
Iron Content (Fe): < 0.3 ppm

Type III Laboratory RO Water Purification System – YR Series
The YR Series is a compact, economical laboratory RO water purification system designed for small laboratories and routine laboratory applications. It converts municipal tap water into purified water with a specified conductivity of 1–5 μS/cm under suitable feed water conditions.
The system features online conductivity monitoring, an LCD control panel, automatic RO flushing, low-pressure protection, and intelligent operation controls. Available production capacities include 10, 15, 20, and 30 L/H, making it suitable for laboratories with relatively low daily water consumption.
Operating Functions
- Unique Seepage source series control system, combined with an intelligent true-color LCD screen, for easy operation;
- Four-stage pretreatment unit, effectively removing particulate matter, iron, manganese, residual chlorine, calcium, magnesium, and adsorbing organic matter, odors, etc.;
- Automatic low-pressure protection for raw water;
- Independent automatic pre-filter backwashing function;
- Online water quality conductivity monitoring function;
- Auto rinse of the reverse osmosis system and discharge of substandard pure water;
- Power-on self-check and automatic power-off protection;
- Automatic alert and protection for low water pressure / water shortage, and automatic standby when the water tank is full;
- With 18-second auto rinse of the reverse osmosis module and the entire system at startup.
10–30 L/H Laboratory RO Water Purification System

| Parameter | Value/Description |
|---|---|
| Model | YR |
| Production Capacity (L/H) | 10 / 15 / 20 / 30 |
| Flow Rate (L/min) | 1.8 – 2.0 |
| Dimensions (HWD) (mm) | 505 × 300 × 405 |
| Power Supply | AC220V / 50Hz or customized (30W) |
| Weight (kg) | 20 – 25 |
| Pure Water Conductivity (μs/cm) | 1 – 5 (online monitoring) |
| Water Tank Configuration | Standard 5G pressure tank (optional specifications available) |
| Applications | Deionized water system for general lab use , teaching laboratory water, replacement for single distillation water purifier, feed water for ultrapure water systems, glassware washing, humidifier / autoclave equipment water. |
40–120 L/H Laboratory RO Water Purification System

| Parameter | Value/Description |
|---|---|
| Model | YRL |
| Production Capacity (L/H) | 40 / 60 / 80 / 100/ 120 |
| Flow Rate (L/min) | 1.8 – 2.0 |
| Dimensions (HWD) (mm) | 1430 × 525 × 570 |
| Power Supply | AC220V / 50Hz or customized (50W-100W) |
| Weight (kg) | 35– 65 |
| Pure Water Conductivity (μs/cm) | 1 – 5 (online monitoring) |
| Water Tank Configuration | Standard 11G-40G pressure tank |
| Applications | Deionized water system for general lab use , teaching laboratory water, replacement for single distillation water purifier, feed water for ultrapure water systems, glassware washing, humidifier / autoclave equipment water. |
Important Notes on Laboratory RO System Performance:
1. Effect of Feed Water Temperature on RO Production Capacity
The rated production capacity is based on RO membrane performance at a feed water temperature of 25°C. As a general estimate, water production may decrease by approximately 3% for every 1°C reduction in temperature. Actual performance depends on membrane characteristics, operating pressure, and feed water conditions.
For installations in colder climates, the expected minimum feed water temperature should be considered when selecting the system capacity. Operation below 5°C is outside the specified feed water temperature range.
2. Effect of Feed Water TDS on Product Water Quality
The standard system specifications are based on feed water with a TDS below 200 ppm. Higher feed water salinity may increase the conductivity of the RO product water and affect the achievable water purity.
For applications requiring lower conductivity, additional purification stages may be necessary. Feed water analysis is recommended before selecting the appropriate system configuration.
Two-Stage RO Laboratory Water Purification System – YS Series
The YS Series is a two-stage reverse osmosis laboratory water purification system designed for laboratories requiring stable, low-conductivity purified water. It treats municipal tap water through pretreatment and a two-stage RO process to reduce dissolved salts and other impurities.
The system features microcomputer-based automatic control, real-time water quality monitoring, automatic RO flushing, and protective functions for reliable daily operation. Depending on the actual configuration, additional polishing stages may be incorporated to produce ultrapure water for applications with higher purity requirements.
Operating Functions
- Unique Seepage source series control system combined with intelligent true-color LCD screen for easy operation;
- Power-on self-check and automatic power-off protection;
- Four-stage raw water pretreatment unit, effectively removing particulate matter, iron, manganese, residual chlorine, calcium, magnesium, and adsorbing organic matter, odors, etc.;
- Two-stage reverse osmosis process, adaptable to various complex raw water conditions, effectively stabilizing product water quality;
- Real-time online monitoring of pure water and ultrapure water quality;
- Auto rinse of the reverse osmosis system, automatic discharge of substandard pure water and ultrapure water;
- Independent pre-treatment backwashing function;
Injection-molded dual-channel pretreatment design, offering long service life and low maintenance cost; - DOW composite membrane technology, providing high water production capacity and good stability;
- Automatic alert and protection for low water pressure / water shortage, and automatic protection when the water tank is full;
10–30 L/H Laboratory RO & Ultrapure Water System – YS Series

The YS Series provides laboratory RO purified water and, depending on the model configuration, ultrapure water with a specified resistivity of up to 18.2 MΩ·cm at 25°C. YS-I, YS-II, and YS-III are designed for different laboratory water quality requirements, ranging from routine laboratory applications to analytical testing requiring higher water purity. Actual water quality depends on feed water conditions, purification configuration, and system maintenance.
| Model | YS-I | YS-II | YS-III |
|---|---|---|---|
| Production Capacity (L/H) | 10 / 15 / 20 / 30 | ||
| Flow Rate (L/min) | 1.8 – 2.0 | ||
| Dimensions (HWD) (mm) | 512 × 390 × 445 | ||
| Power Supply | AC220V / 50Hz or customized (30W) | ||
| Weight (kg) | 30 – 50 | ||
| Pure Water Conductivity (μs/cm) | 2 – 10 (online monitoring) | 1 – 5 (online monitoring) | 1 – 5 (online monitoring) |
| Resistivity (MΩ·cm @25°C) | 15 – 18 (online monitoring) | 18.2 (online monitoring) | 18.2 (online monitoring) |
| Microorganisms (cfu/ml) | — | ≤1 | ≤1 |
| Micro-particles (particles/ml) | — | ≤1 | ≤1 |
| Heavy Metal Ions (ppb) | — | — | ≤0.1 |
| Oxidizable Substances (as O) (mg/L) | — | ≤0.4 | ≤0.4 |
| Absorbance (254nm, 1cm path length) | — | ≤0.001 | ≤0.001 |
| Silica (mg/L) | — | ≤0.2 | ≤0.2 |
| Evaporation Residue (mg/L) | — | <1.0 | <1.0 |
| Applications | Sustainable lab water for general biochemical experiments, aging tests, glassware washing, humidifier / autoclave water supply | Best lab water system for analytical chemistry, general qualitative/quantitative analysis, suitable for atomic absorption, atomic emission, UV spectrophotometry, etc. | Biomedicine, pharmaceutical, environmental science, surface science, as well as atomic absorption, atomic emission, ion chromatography, HPLC, etc. |
40–120 L/H Laboratory RO & Ultrapure Water System – YSL-A Series

| Model | YSL-A-I | YSL-A-II | YSL-A-III |
|---|---|---|---|
| Production Capacity (L/H) | 40 / 60 / 80 / 100 / 120 | ||
| Flow Rate (L/min) | 1.8 – 2.0 | ||
| Dimensions (HWD) (mm) | 1430 × 525 × 570 | ||
| Power Supply | AC220V / 50Hz or customized (50-100W) | ||
| Weight (kg) | 80 | ||
| Pure Water Conductivity (μs/cm) | 2 – 10 (online monitoring) | 1 – 5 (online monitoring) | 1 – 5 (online monitoring) |
| Resistivity (MΩ·cm @25°C) | 15 – 18 (online monitoring) | 18.2 (online monitoring) | 18.2 (online monitoring) |
| Microorganisms (cfu/ml) | — | ≤0.1 | ≤0.1 |
| Micro-particles (particles/ml) | — | ≤1 | ≤1 |
| Heavy Metal Ions (ppb) | — | — | ≤0.1 |
| Oxidizable Substances (as O) (mg/L) | ≤0.4 | ≤0.4 | ≤0.4 |
| Absorbance (254nm, 1cm path length) | ≤0.001 | ≤0.001 | ≤0.001 |
| Silica (mg/L) | ≤0.2 | ≤0.2 | ≤0.2 |
| Evaporation Residue (mg/L) | <1.0 | <1.0 | <1.0 |
| Applications | Sustainable lab water for general biochemical experiments, aging tests, glassware washing, humidifier / autoclave water supply | Best lab water system for analytical chemistry, general qualitative/quantitative analysis, suitable for atomic absorption, atomic emission, UV spectrophotometry, etc. | Biomedicine, pharmaceutical, environmental science, surface science, as well as atomic absorption, atomic emission, ion chromatography, HPLC, etc. |
Type I & Type III Laboratory Water Purification System – YZ Series
The YZ Series laboratory water purification system is designed to produce RO purified water and ultrapure water for routine laboratory work and analytical applications. With a two-stage reverse osmosis process and additional purification stages, the system offers a specified ultrapure water resistivity of up to 18.25 MΩ·cm at 25°C, depending on feed water conditions and system configuration.
The system features an intelligent touchscreen controller, online conductivity and resistivity monitoring, programmable water dispensing, automatic flushing, and timed water recirculation. Available production capacities range from 10 to 30 L/H, with different configurations for analytical testing, life science research, and applications requiring additional water quality control.

10L-30L
Operating Functions
- Unique Seepage source series control system combined with an intelligent touch-screen LCD display for easy operation and clear readouts, greatly improving work efficiency;
- The equipment provides historical data inquiry for water dispensing, along with online display of time, temperature, and water quality;
- Four-stage pretreatment unit with high-quality media and a pretreatment detection device, effectively removing particulate matter, iron, manganese, residual chlorine, calcium, magnesium, and adsorbing organic matter, odors, etc.;
- Two-stage reverse osmosis process, adaptable to various complex raw water conditions, effectively stabilizing product water quality;
- The system allows setting of a quantitative dispensing function; dispensing water quality and volume can be configured with password-protected access;
- Automatic flushing of the reverse osmosis system and automatic discharge of substandard pure water and ultrapure water;
- Password setting function to prevent unauthorized access to internal parameter changes or improper operations;
- Automatic recirculation at set time intervals to prevent secondary contamination of ultrapure water, ensuring ultrapure water remains stable at 18.25 MΩ·cm;
- Audible, visual, and silent text alarms for water shortage, low water tank level, water quality below standard, etc.;
- Automatic alert and protection for low water pressure / water shortage, and automatic protection when the water tank is full; additionally equipped with an overflow port to prevent adverse effects on the laboratory from tank overflow in case of level sensor failure;
- Can store water dispensing logs, alarm logs, and other operation logs for up to two years;
- The pure water tank features a conical bottom with a drain valve at the base, facilitating cleaning and disinfection;
Water Quality Monitoring & Maintenance Features
- Snap-in internal mounting design for easy replacement of consumables by engineers and customers;
- Consumables replacement reminder function to ensure product water quality meets national standards and industry water requirements;
- The water tank is equipped with functions for chemical dosing, cleaning, and disinfection;
Optional UV disinfection unit for the injection-molded water tank; - The system is equipped with a terminal microfiltration unit to ensure the reliability of the water quality at the point of use;
- Optional online TOC detection device to display TOC values;
- 2 models are lab water system for endotoxin removal
| Model | YZ | YZ-F | YZ-V | YZ-VF |
|---|---|---|---|---|
| Production Capacity (L/H) | 10 / 15 / 20 / 30 | |||
| Flow Rate (L/min) | 1.8 – 2.0 | |||
| Dimensions (H*W*D) (mm) | 580 × 390 × 490 | |||
| Power Supply | AC220V / 50Hz or customized (30W) | |||
| Weight (kg) | 30 – 50 | |||
| Pure Water Conductivity (μs/cm) | 1 – 5 (online monitoring) | |||
| Resistivity (MΩ·cm @25°C) | 18.25 (online monitoring) | |||
| Microorganisms (cfu/ml) | ≤0.1 | |||
| Micro-particles (particles/ml) | ≤1 | |||
| Heavy Metal Ions (ppb) | ≤0.1 | |||
| TOC (ppb) | ≤20 | ≤20 | ≤10 | ≤10 |
| Absorbance (254nm, 1cm path length) | ≤0.001 | |||
| Soluble Silica (mg/L) | ≤0.01 | |||
| Pyrogen (Endotoxin) (Eu/ml) | —— | ≤0.001 | —— | ≤0.001 |
| Evaporation Residue (mg/L) | <1.0 | |||
| Applications | HPLC, IC, ICP, PCR, AAS, AFS, clinical labs, buffer preparation, etc. | Biomedicine, environmental science, atomic emission, ion chromatography, liquid and gas chromatography, amino acid analysis, electrophoresis/gel analysis, toxicology research | HPLC, TOC, VOC, ICP-MS, PCR, research lab, etc. | HPLC, TOC, VOC, PCR, IC, IVF, ICP-MS, electrochemical interface, animal and plant cell culture, hydroponics,gene research, IVF and other life science experiments,immunochemistry,mass spectrometry |

40–120 L/H Laboratory RO & Ultrapure Water System – YZL Series
| Model | YZL | YZL-F | YZL-V | YZL-VF |
|---|---|---|---|---|
| Production Capacity (L/H) | 40 / 60 /100 / 120 | |||
| Flow Rate (L/min) | 1.8 – 2.0 | |||
| Dimensions (H*W*D) (mm) | 1430 × 525 × 570 | |||
| Power Supply | AC220V / 50Hz or customized (50-100W) | |||
| Weight (kg) | 80 | |||
| Pure Water Conductivity (μs/cm) | 1 – 5 (online monitoring) | |||
| Resistivity (MΩ·cm @25°C) | 18.25 (online monitoring) | |||
| Microorganisms (cfu/ml) | ≤0.1 | |||
| Micro-particles (particles/ml) | ≤1 | |||
| Heavy Metal Ions (ppb) | ≤0.1 | |||
| TOC (ppb) | ≤20 | ≤20 | ≤10 | ≤10 |
| Absorbance (254nm, 1cm path length) | ≤0.001 | |||
| Soluble Silica (mg/L) | ≤0.01 | |||
| Pyrogen (Endotoxin) (Eu/ml) | —— | ≤0.001 | —— | ≤0.001 |
| Evaporation Residue (mg/L) | <1.0 | |||
| Applications | HPLC, IC, ICP, PCR, AAS, AFS, clinical labs, buffer preparation, etc. | Biomedicine, environmental science, atomic emission, ion chromatography, liquid and gas chromatography, amino acid analysis, electrophoresis/gel analysis, toxicology research | HPLC, TOC, VOC, ICP-MS, PCR, research lab, etc. | HPLC, TOC, VOC, PCR, IC, IVF, ICP-MS, electrochemical interface, animal and plant cell culture, hydroponics,gene research, IVF and other life science experiments,immunochemistry,mass spectrometry |
RO + EDI Laboratory Ultrapure Water System – YH Series
The YH Series laboratory ultrapure water purification system combines reverse osmosis (RO), electrodeionization (EDI), UV treatment, and ultrafiltration (UF) to produce high-purity water for advanced laboratory applications.
Designed for analytical laboratories, life science research, and pharmaceutical R&D, the system features online water quality monitoring, a touchscreen control interface, real-time TOC monitoring, automatic RO flushing, and programmable water dispensing.
Additional features include remote monitoring via a mobile app, leak detection, automatic water quality alarms, and operation data logging. The YH Series is suitable for laboratories requiring advanced water quality control, automated operation, and flexible dispensing options.
Operating Functions
- Unique Seepage source series control system combined with a high-resolution touch screen for easy operation and clear display;
- Online monitoring function, displaying water temperature, raw water quality, EDI product water quality, EDI product water flow rate, and RO/UP dispensing water quality in real time;
- Built-in independent online TOC (Total Organic Carbon) monitoring module with real-time TOC value display;
- Two-stage reverse osmosis process, with percentage display of RO membrane salt rejection rate; fully automatic RO membrane flushing with user-adjustable flushing time; automatic rejection of substandard RO product water;
- Adopts EDI technology and modules to reduce operating costs and wastewater discharge;
- The system features a percentage level display for accurate water tank level indication;
- The water tank is equipped with a UV sterilization system with programmable timed disinfection; tapered bottom design with a bottom drain valve for easy cleaning;
- The system includes a UV sterilization unit and an UF ultrafiltration membrane to effectively kill bacteria, remove pyrogens, and reduce TOC content;
- Password protection function to prevent unauthorized access to internal parameter changes or improper operations;
- The system features power-on self-test, low water protection, automatic reset after power failure, and automatic low-pressure shutdown protection;
- The system can store water dispensing logs, alarm logs, and other operation logs for up to two years;
Quantitative dispensing function with user-configurable water quality and volume; four adjustable dispensing speeds; - Equipped with a mobile dispensing arm featuring remote/sensor-activated dispensing for greater convenience;
- Leak detection module; automatically shuts off the water supply in case of a leak;
- Alarm function with online display of consumable status; audible, visual, and silent text alerts for low water, low tank level, or substandard water quality;
- Remote monitoring function; equipment operation status can be remotely monitored via a mobile APP.

10–30 L/H RO + EDI Laboratory Ultrapure Water System – YH Series
| Model | YH | YH-F | YH-V | YH-VF |
|---|---|---|---|---|
| Production Capacity (L/H) | 10 / 15 / 20 / 30 | |||
| Flow Rate (L/min) | 1.8 – 2.0 | |||
| Dimensions (HWD) (mm) | 650 × 530 × 420 | |||
| Power Supply | AC220V/50Hz ±5% or customized (35W) | |||
| Weight (kg) | 30 – 50 | |||
| Pure Water Conductivity (μs/cm) | 1 – 5 (online monitoring) | |||
| Resistivity (MΩ·cm @25°C) | 18.25 (online monitoring) | |||
| Microorganisms (cfu/ml) | ≤0.1 | |||
| Micro-particles (particles/ml) | ≤1 | |||
| Heavy Metal Ions (ppb) | ≤0.1 | |||
| TOC (ppb) | ≤5 | ≤5 | ≤3 | ≤3 |
| Absorbance (254nm, 1cm path length) | ≤0.001 | |||
| Soluble Silica (mg/L) | ≤0.01 | |||
| Pyrogen (Endotoxin) (Eu/ml) | —— | ≤0.001 | —— | ≤0.001 |
| Evaporation Residue (mg/L) | <1.0 | |||
| Applications | Geochemistry, materials science, biomedicine, IC, ICP, AAS | Liquid/gas chromatography, amino acid analysis, electrophoresis/gel analysis, toxicology research, animal & plant cell culture, and other molecular biology experiments | HPLC, TOC, ICP, PCR, IVF, GC-MS, animal & plant cell culture, electrochemical interface, gravimetric analysis | HPLC, IC, ICP-MS, IVF, PCR, TOC, electrochemical interface, animal & plant cell culture, gene research, IVF and other life science experiments |

40–120 L/H RO + EDI Laboratory Ultrapure Water System – YHL Series
| Model | YHL | YHL-F | YHL-V | YHL-VF |
|---|---|---|---|---|
| Production Capacity (L/H) | 40 /60 / 80 / 100/ 120 | |||
| Flow Rate (L/min) | 1.8 – 2.0 | |||
| Dimensions (HWD) (mm) | 1430 × 525 × 570 | |||
| Power Supply | AC220V/50Hz ±5% or customized (50-100W) | |||
| Weight (kg) | 80 | |||
| Pure Water Conductivity (μs/cm) | 1 – 5 (online monitoring) | |||
| Resistivity (MΩ·cm @25°C) | 18.25 (online monitoring) | |||
| Microorganisms (cfu/ml) | ≤0.1 | |||
| Micro-particles (particles/ml) | ≤1 | |||
| Heavy Metal Ions (ppb) | ≤0.1 | |||
| TOC (ppb) | ≤5 | ≤5 | ≤3 | ≤3 |
| Absorbance (254nm, 1cm path length) | ≤0.001 | |||
| Soluble Silica (mg/L) | ≤0.01 | |||
| Pyrogen (Endotoxin) (Eu/ml) | —— | ≤0.001 | —— | ≤0.001 |
| Evaporation Residue (mg/L) | <1.0 | |||
| Applications | Geochemistry, materials science, biomedicine, IC, ICP, AAS | Liquid/gas chromatography, amino acid analysis, electrophoresis/gel analysis, toxicology research, animal & plant cell culture, and other molecular biology experiments | HPLC, TOC, ICP, PCR, IVF, GC-MS, animal & plant cell culture, electrochemical interface, gravimetric analysis | HPLC, IC, ICP-MS, IVF, PCR, TOC, electrochemical interface, animal & plant cell culture, gene research, IVF and other life science experiments |
How to Choose the Right Laboratory Water Purification System
| Series | Water treatment | Capacity | Main application |
|---|---|---|---|
| YR / YRL | RO | 10–120 L/H | General laboratory pure water |
| YS / YSL-A | RO + ultrapure polishing | 10–120 L/H | Analytical and research laboratories |
| YZ / YZL | RO + ultrapure polishing | 10–120 L/H | Type I and Type III laboratory water |
| YH / YHL | RO + EDI + UV/UF | 10–120 L/H | Advanced analytical and life science laboratories |