CDL/CDLF Vertical Multistage Pump Operating Conditions
- Suitable Liquids: Thin, clean, non-flammable and non-explosive liquids without solid particles or fibers.
- Liquid Temperature:
Standard version: −15°C to +70°C
High-temperature version: −15°C to +120°C
Maximum Ambient Temperature: +40°C
Installation Altitude: Up to 1,000 m above sea level under standard operating conditions.
CDL/CDLF Vertical Multistage Pump Construction
The CDL/CDLF series is a non-self-priming vertical multistage centrifugal pump designed for industrial reverse osmosis and water treatment applications.
The motor shaft is connected to the pump shaft through a coupling at the pump head. Tie bolts secure the pump casing and hydraulic components between the pump head and the suction/discharge section. The suction and discharge ports are positioned on the same axis at the pump base.
An optional motor protection device can be provided to help protect against dry running, phase loss, overload and other abnormal operating conditions, depending on the selected configuration.
CDL/CDLF Pump Motor Specifications
The CDL/CDLF vertical multistage pump can be equipped with a totally enclosed, fan-cooled (TEFC) motor, with electrical specifications selected according to the pump model and project requirements.
Motor Type: Two-pole, fan-cooled motor
Protection Class: IP55
Insulation Class: F
Frequency: 50 Hz / 60 Hz
Available Voltage Configurations:
Single-phase: 220–240 V
Three-phase: 200–220 V / 346–380 V
Three-phase: 220–240 V / 380–415 V
Three-phase: 380–415 V
Motor voltage, frequency and power should be confirmed for the selected pump model before ordering.
CDL/CDLF Vertical Multistage Pump Assembly Video
Watch the assembly process of a CDL/CDLF vertical multistage centrifugal pump, including its pump casing and internal components. These pumps are commonly used for pressure boosting in industrial reverse osmosis and water treatment systems.
For an overview of vertical and horizontal pump options, explore our RO multistage booster pumps.
CDL/CDLF Vertical Multistage Pump Models & Specifications

| Model | Rated Flow (m3/hour) | Max Pressure(bar) |
|---|---|---|
| CDL(F)1 | 1 | 21 |
| 2 | 23 | |
| CDL(F)3 | 3 | 22 |
| CDL(F)4 | 4 | 21 |
| CDL(F)8 | 8 | 21 |
| CDL(F)12 | 12 | 22 |
| CDL(F)16 | 16 | 22 |
| CDL(F)20 | 20 | 23 |
| CDL(F)32 | 32 | 26 |
| CDL(F)42 | 42 | 30 |
| CDL(F)65 | 65 | 22 |
| CDL(F)82 | 82 | 17 |
| CDL(F)120 | 120 | 16 |
| CDL(F)150 | 150 | 16 |
Note: The rated flow and maximum pressure values shown above represent the available pump series specifications and may not occur at the same operating point. Actual pump selection should be based on the required flow rate, discharge pressure, pump performance curve, motor power and operating conditions.
CDL/CDLF Vertical Multistage Pump Applications in RO Systems
High Pressure Pump For RO System
CDL/CDLF vertical multistage pumps are widely used for pressure boosting in industrial reverse osmosis systems and other water treatment applications. Depending on the required flow rate and operating pressure, these pumps can be integrated into RO skids, filtration systems and industrial water supply installations.
The following images illustrate vertical multistage pumps installed in different water treatment and pressure boosting configurations. Pump selection should be based on the system operating point, water quality and installation requirements.




CDL/CDLF Vertical Multistage Pump FAQ
What are CDL/CDLF vertical multistage pumps used for?
CDL/CDLF vertical multistage centrifugal pumps are used for pressure boosting in industrial reverse osmosis systems, water treatment equipment and industrial water supply applications. Their vertical design is suitable for installations where floor space is limited. Pump selection depends on the required flow rate, operating pressure and water quality.
What information is required to select a CDL/CDLF pump?
Please provide the required flow rate (m³/h), operating pressure or total dynamic head, feed water quality, liquid temperature, available voltage and frequency. If the pump is intended for an RO system, information about the RO capacity and operating pressure will also help us identify a suitable model.
What materials are available for CDL/CDLF pumps?
CDL/CDLF pumps are available in different material configurations, including stainless steel options. The materials used for wetted components and mechanical seals depend on the specific model and application. Material compatibility should be confirmed based on the water composition, temperature and operating conditions.
Can CDL/CDLF vertical multistage pumps be used for seawater RO systems?
Standard CDL/CDLF pumps should not automatically be considered suitable for seawater applications. Seawater has a high chloride concentration and requires appropriate corrosion-resistant materials, seals and pressure ratings. For seawater reverse osmosis systems, pump suitability must be verified against the actual operating conditions and manufacturer specifications.
Can CDL/CDLF pumps be supplied for different voltage and frequency requirements?
Different motor configurations may be available depending on the pump model, including 50 Hz and 60 Hz options. Please confirm the required voltage, frequency and phase when requesting a quotation. Motor specifications and availability will be checked for the selected model.