Replacement UF Membrane Modules | PVC & PVDF Supplier

Our PVC and PVDF replacement UF membrane modules provide alternative options for existing industrial ultrafiltration systems. Designed for membrane replacement and system maintenance, these modules help water treatment companies and system integrators source compatible alternatives to selected original UF membrane models.

Key Advantages:

  • Brand Replacement Options: Alternative UF membrane modules for selected international and Chinese membrane brands.
  • Dimensional Compatibility: Matching options for membrane dimensions, connection interfaces and installation requirements.
  • Reduced Modification Costs: Direct-fit replacement may be possible for verified models, minimizing piping modifications and system downtime.
  • PVC & PVDF Options: Different membrane materials and configurations for industrial water treatment applications.
  • Technical Matching Support: Compatibility assessment based on existing membrane model numbers, dimensions and operating parameters.
  • B2B Sourcing: Replacement UF membrane sourcing and supplier coordination for distributors, engineering companies and system integrators.

**Send us your existing UF membrane brand, model number or technical

  • Replacement UF Membrane Modules for Industrial Water Treatment

    Clear Environment supplies PVC and PVDF replacement UF membrane modules for existing industrial ultrafiltration systems. We help water treatment companies, distributors and system integrators identify compatible membrane alternatives for equipment maintenance and replacement projects.

    Key Benefits of Our Replacement UF Membranes

    • Alternative Membrane Options: Replacement options for selected UF membrane brands and models.

    • Compatibility Matching: Evaluation of membrane dimensions, connection interfaces, filtration direction and operating parameters.

    • Reduced Replacement Costs: Compatible alternatives may help reduce membrane replacement expenses compared with original branded modules.

    • Efficient Filtration Performance: Available configurations can be selected according to required membrane flux, filtration precision and operating conditions.

    • Simplified Installation: Direct-fit replacement may be possible for verified models, reducing the need for piping modifications.

    • Technical Sourcing Support: Assistance with product selection, supplier coordination and technical specification comparison.

    How to Find a Compatible UF Membrane Replacement

    To check replacement compatibility, please provide the following information:

    • Existing UF membrane brand and model number

    • Membrane module dimensions and connection details

    • Membrane material (PVC, PVDF or other)

    • Filtration direction (inside-out or outside-in)

    • Operating pressure, membrane area and required flow rate

    Looking for a replacement UF membrane supplier in China? Send us your existing membrane specifications or technical drawings for compatibility assessment and quotation.

PVC & PVDF Replacement UF Membrane Models & Technical Specifications

Replacement UF Membrane Module Specifications

The following table compares five PVC and PVDF replacement UF membrane module models, including membrane area, design permeate flow, connection sizes, operating conditions and cleaning requirements.

For replacement projects, matching the membrane area and flow capacity alone is not sufficient. Module dimensions, connection interfaces, filtration direction and backwashing requirements should also be verified against the existing UF system.

ModelUF225-CPA60UF-1060UF219-XFLOW55LUF-2860UF-2880
PerformanceMembrane materialPVCPVDF
Inner and outer diameter dimensions of membrane fibers1.0mm/1.7mm0.7mm/1.3mm
Cutting molecular weight100000 Dalton
Design water production1500-3000L/H2000-4000L/H1500-3000L/H1500-4000L/H2000-6000L/H
Effective external pressure membrane area (㎡)4043405177
Water inlet and outlet interfaceDN50(Ø63)DN50(Ø63)DN65(Ø75)DN50(Ø63)DN50(Ø63)
Housing materialUPVC
End sealing materialEpoxy resin
Working conditionPretreatment50-150μm
Operation ModeInternal pressure operationExternal pressure operation
Working pressure0.02-0.2MPa
Maximum inlet pressure0.3MPa
Maximum transmembrane pressure difference0.2MPa
pH2-12
Continuous residual chlorine concentration is tolerable100ppm1000ppm
Intermittent residual chlorine concentration is tolerable200ppm2000ppm
Working temperature1℃-40℃
Inlet water qualityTurbidity≤50NTU
Water outlet parameters* Turbidity of produced water<15NTU<50NTU
* SDI<1
Particle100% removal rate
* Microorganisms, pathogens99.99% removal rate
Backwash designBackwash frequencyEach 15-60 minutes
Backwash pressure≤0.2MPa
Backwash Flow100-150L/H.㎡
Backwash chemical15-20ppm NaClO500ppm NaClO
Backwash with chemical frequencySuggest automatic backwashing every time medicationSuggest conducting chemical enhanced backwashing within 1-7 days
Chemical cleaning designChemical cleaning frequencyOnce every 1-4 months
Acid chemicalCitric acid oxalic acid or hydrochloric acid (solution with pH=2)
Alkaline chemicalNaOH+NaClO (solution with pH=2)
*Indicates testing with municipal tap water

UF Membrane Replacement Applications & Project References

UF Membrane Replacement for Chemical & Oil Industry Water Reuse

Project Capacity: 9,500 tons/day

Application: Industrial water reuse in the chemical and oil industry

UF Membrane Type: PVDF hollow fiber, inside-out filtration

Replacement Membrane Model: UF219-XLOW55

Quantity: 248 modules

Original Membrane Brand: Norit

This project demonstrates the use of alternative UF membrane modules in an industrial water reuse application. Replacement compatibility should be evaluated based on membrane dimensions, connection interfaces and operating requirements.

UF Membrane Replacement for Thermal Power Plant Water Treatment

Project Capacity: 3,000 tons/day

Application: Ultrafiltration pretreatment for ultrapure water production

UF Membrane Type: PVDF hollow fiber, inside-out filtration

Replacement Membrane Model: UF219-XLOW64

Quantity: 40 modules

This project illustrates the application of UF membrane replacement modules in power plant water treatment, where membrane performance, filtration stability and compatibility with the existing system are important selection factors.

Replacement UF Membrane Module Features

UF membrane module end connection for replacement

Durable UF Membrane Connections

The UF membrane module features reinforced connection components designed for reliable installation and operation. Connection dimensions and interface compatibility can be checked against existing membrane modules to support replacement projects.

Hollow fiber UF membrane module end structure

UF Membrane Filtration Performance

Available in different PVC and PVDF membrane configurations, these replacement UF modules are designed for industrial water filtration applications. Membrane material, filtration area, operating pressure and flow capacity can be selected according to system requirements.

Industrial replacement UF membrane modules

OEM & Customized UF Membrane Replacement

Clear Environment works with Chinese UF membrane suppliers to support OEM and customized replacement requirements. Membrane dimensions, connection interfaces and configurations can be evaluated based on customers’ existing module specifications, technical drawings or samples.

Replacement UF Membrane – Frequently Asked Questions

1. Can you provide replacement UF membranes for major international brands?

Yes. Clear Environment sources alternative UF membrane modules for selected international brands, including replacement options for certain Norit membrane models. Compatibility depends on the original module dimensions, connection interfaces, membrane specifications and operating conditions. Please provide the existing brand and model number for verification.

2. Can your replacement UF membranes fit existing systems without piping modifications?

Direct-fit replacement may be possible for compatible models. Before confirming, we check the module dimensions, inlet and outlet connections, filtration direction and operating parameters. Some installations may require adapters or modifications.

3. What membrane materials are available for UF membrane replacement?

We offer PVC and PVDF replacement UF membrane options for industrial water treatment applications. Different membrane configurations are available depending on the required filtration performance, operating pressure, chemical compatibility and existing system design.

4. What information do you need to identify a compatible UF membrane replacement?

Please provide the original membrane brand, model number, module dimensions, connection details, membrane area and operating conditions. Technical drawings or photos of the existing membrane module are also helpful for compatibility assessment.

5. Do you support OEM and customized UF membrane replacement modules?

Yes. Clear Environment works with Chinese UF membrane suppliers to support OEM and customized replacement requirements. Available dimensions, connection configurations, minimum order quantities and customization options depend on the selected model and supplier.

6. Can you supply replacement UF membranes for industrial water treatment projects?

Yes. We support distributors, engineering companies and system integrators sourcing replacement UF membrane modules for industrial water reuse, RO pretreatment, power plant water treatment and other ultrafiltration applications. Please share your project requirements and required quantity for technical matching and quotation.

RELATED PRODUCT

RELATED PRODUCT

Scroll to Top

Send your inquiry today