Replacement UF Membrane Modules for Industrial Water Treatment
Clear Environment supplies PVC and PVDF replacement UF membrane modules for existing industrial ultrafiltration systems. We help water treatment companies, distributors and system integrators identify compatible membrane alternatives for equipment maintenance and replacement projects.
Key Benefits of Our Replacement UF Membranes
Alternative Membrane Options: Replacement options for selected UF membrane brands and models.
Compatibility Matching: Evaluation of membrane dimensions, connection interfaces, filtration direction and operating parameters.
Reduced Replacement Costs: Compatible alternatives may help reduce membrane replacement expenses compared with original branded modules.
Efficient Filtration Performance: Available configurations can be selected according to required membrane flux, filtration precision and operating conditions.
Simplified Installation: Direct-fit replacement may be possible for verified models, reducing the need for piping modifications.
Technical Sourcing Support: Assistance with product selection, supplier coordination and technical specification comparison.
How to Find a Compatible UF Membrane Replacement
To check replacement compatibility, please provide the following information:
Existing UF membrane brand and model number
Membrane module dimensions and connection details
Membrane material (PVC, PVDF or other)
Filtration direction (inside-out or outside-in)
Operating pressure, membrane area and required flow rate
Looking for a replacement UF membrane supplier in China? Send us your existing membrane specifications or technical drawings for compatibility assessment and quotation.
PVC & PVDF Replacement UF Membrane Models & Technical Specifications
Replacement UF Membrane Module Specifications
The following table compares five PVC and PVDF replacement UF membrane module models, including membrane area, design permeate flow, connection sizes, operating conditions and cleaning requirements.
For replacement projects, matching the membrane area and flow capacity alone is not sufficient. Module dimensions, connection interfaces, filtration direction and backwashing requirements should also be verified against the existing UF system.
| Model | UF225-CPA60 | UF-1060 | UF219-XFLOW55 | LUF-2860 | UF-2880 | |
|---|---|---|---|---|---|---|
| Performance | Membrane material | PVC | PVDF | |||
| Inner and outer diameter dimensions of membrane fibers | 1.0mm/1.7mm | 0.7mm/1.3mm | ||||
| Cutting molecular weight | 100000 Dalton | |||||
| Design water production | 1500-3000L/H | 2000-4000L/H | 1500-3000L/H | 1500-4000L/H | 2000-6000L/H | |
| Effective external pressure membrane area (㎡) | 40 | 43 | 40 | 51 | 77 | |
| Water inlet and outlet interface | DN50(Ø63) | DN50(Ø63) | DN65(Ø75) | DN50(Ø63) | DN50(Ø63) | |
| Housing material | UPVC | |||||
| End sealing material | Epoxy resin | |||||
| Working condition | Pretreatment | 50-150μm | ||||
| Operation Mode | Internal pressure operation | External pressure operation | ||||
| Working pressure | 0.02-0.2MPa | |||||
| Maximum inlet pressure | 0.3MPa | |||||
| Maximum transmembrane pressure difference | 0.2MPa | |||||
| pH | 2-12 | |||||
| Continuous residual chlorine concentration is tolerable | 100ppm | 1000ppm | ||||
| Intermittent residual chlorine concentration is tolerable | 200ppm | 2000ppm | ||||
| Working temperature | 1℃-40℃ | |||||
| Inlet water quality | Turbidity≤50NTU | |||||
| Water outlet parameters | * Turbidity of produced water | <15NTU | <50NTU | |||
| * SDI | <1 | |||||
| Particle | 100% removal rate | |||||
| * Microorganisms, pathogens | 99.99% removal rate | |||||
| Backwash design | Backwash frequency | Each 15-60 minutes | ||||
| Backwash pressure | ≤0.2MPa | |||||
| Backwash Flow | 100-150L/H.㎡ | |||||
| Backwash chemical | 15-20ppm NaClO | 500ppm NaClO | ||||
| Backwash with chemical frequency | Suggest automatic backwashing every time medication | Suggest conducting chemical enhanced backwashing within 1-7 days | ||||
| Chemical cleaning design | Chemical cleaning frequency | Once every 1-4 months | ||||
| Acid chemical | Citric acid oxalic acid or hydrochloric acid (solution with pH=2) | |||||
| Alkaline chemical | NaOH+NaClO (solution with pH=2) | |||||
| *Indicates testing with municipal tap water | ||||||
UF Membrane Replacement Applications & Project References

UF Membrane Replacement for Chemical & Oil Industry Water Reuse
Project Capacity: 9,500 tons/day
Application: Industrial water reuse in the chemical and oil industry
UF Membrane Type: PVDF hollow fiber, inside-out filtration
Replacement Membrane Model: UF219-XLOW55
Quantity: 248 modules
Original Membrane Brand: Norit
This project demonstrates the use of alternative UF membrane modules in an industrial water reuse application. Replacement compatibility should be evaluated based on membrane dimensions, connection interfaces and operating requirements.
UF Membrane Replacement for Thermal Power Plant Water Treatment
Project Capacity: 3,000 tons/day
Application: Ultrafiltration pretreatment for ultrapure water production
UF Membrane Type: PVDF hollow fiber, inside-out filtration
Replacement Membrane Model: UF219-XLOW64
Quantity: 40 modules
This project illustrates the application of UF membrane replacement modules in power plant water treatment, where membrane performance, filtration stability and compatibility with the existing system are important selection factors.
Replacement UF Membrane Module Features

Durable UF Membrane Connections
The UF membrane module features reinforced connection components designed for reliable installation and operation. Connection dimensions and interface compatibility can be checked against existing membrane modules to support replacement projects.

UF Membrane Filtration Performance
Available in different PVC and PVDF membrane configurations, these replacement UF modules are designed for industrial water filtration applications. Membrane material, filtration area, operating pressure and flow capacity can be selected according to system requirements.

OEM & Customized UF Membrane Replacement
Clear Environment works with Chinese UF membrane suppliers to support OEM and customized replacement requirements. Membrane dimensions, connection interfaces and configurations can be evaluated based on customers’ existing module specifications, technical drawings or samples.
Replacement UF Membrane – Frequently Asked Questions
1. Can you provide replacement UF membranes for major international brands?
Yes. Clear Environment sources alternative UF membrane modules for selected international brands, including replacement options for certain Norit membrane models. Compatibility depends on the original module dimensions, connection interfaces, membrane specifications and operating conditions. Please provide the existing brand and model number for verification.
2. Can your replacement UF membranes fit existing systems without piping modifications?
Direct-fit replacement may be possible for compatible models. Before confirming, we check the module dimensions, inlet and outlet connections, filtration direction and operating parameters. Some installations may require adapters or modifications.
3. What membrane materials are available for UF membrane replacement?
We offer PVC and PVDF replacement UF membrane options for industrial water treatment applications. Different membrane configurations are available depending on the required filtration performance, operating pressure, chemical compatibility and existing system design.
4. What information do you need to identify a compatible UF membrane replacement?
Please provide the original membrane brand, model number, module dimensions, connection details, membrane area and operating conditions. Technical drawings or photos of the existing membrane module are also helpful for compatibility assessment.
5. Do you support OEM and customized UF membrane replacement modules?
Yes. Clear Environment works with Chinese UF membrane suppliers to support OEM and customized replacement requirements. Available dimensions, connection configurations, minimum order quantities and customization options depend on the selected model and supplier.
6. Can you supply replacement UF membranes for industrial water treatment projects?
Yes. We support distributors, engineering companies and system integrators sourcing replacement UF membrane modules for industrial water reuse, RO pretreatment, power plant water treatment and other ultrafiltration applications. Please share your project requirements and required quantity for technical matching and quotation.