LP Series Conventional Brackish Water RO Membrane Elements

The LP Series low-pressure brackish water RO membrane elements are designed for desalination of brackish groundwater and surface water. They offer high salt rejection, reliable permeate flow, and stable performance under suitable operating conditions.

These membranes are suitable for industrial water purification, drinking water treatment, boiler feed water preparation, and process water production in the electronics and power industries.

Clear Environment supplies LP Series RO membrane elements for new installations and membrane replacement projects, with model selection and sourcing support based on feed water quality and system requirements.

Product Advantages of LP Series Brackish Water RO Membranes

  • Low-pressure operation: Designed for brackish water desalination, offering reliable permeate flow and salt rejection under suitable operating conditions.

  • Stable separation performance: Suitable for continuous operation in industrial and commercial RO water treatment systems.

  • Versatile applications: Applicable to brackish groundwater, surface water, industrial process water, and boiler feed water preparation, subject to feed water quality and pretreatment.

  • 4040 and 8040 membrane options: Model selection can be based on required permeate capacity, feed water conditions, and existing RO system specifications.

Operating Limits of LP Series RO Membrane Elements

  • Maximum operating pressure: 41 bar (600 psi)

  • Maximum operating temperature: 45°C (113°F)

  • Maximum pressure drop per element: 1.0 bar (15 psi)

  • Continuous operating pH range: 2–11

  • Chemical cleaning pH range: 1–13

  • Maximum feed water SDI15: 5.0

  • Free chlorine: Below 0.1 ppm, with dechlorination recommended before the RO membranes

Important: The maximum operating pressure is a design limit, not the recommended operating pressure. Actual operating pressure depends on feed water salinity, temperature, recovery rate, and membrane model.

Performance Notes

  • Individual membrane element permeate flow may vary by ±15%.

  • Effective membrane area may vary by ±4%.

  • Salt rejection performance may stabilize after 24–48 hours of operation, depending on feed water quality and operating conditions.

  • Refer to the specific membrane model datasheet for test conditions and performance ratings.

Applications of LP Series Brackish Water RO Membranes

LP series brackish water RO membrane elements

LP Series brackish water RO membrane elements are designed for desalination of moderately saline feed water, with a stated application range of approximately 2,000–8,000 ppm TDS. Actual membrane selection and system performance depend on feed water composition, operating pressure, temperature, and recovery rate.

Typical Feed Water Sources

  • Brackish groundwater

  • Saline surface water

  • Pre-treated reclaimed water

  • Pre-treated industrial wastewater, where feed water quality meets membrane requirements

Industrial Applications

  • Industrial process water production

  • Boiler feed water preparation

  • Textile and chemical manufacturing

  • Petrochemical water treatment

  • Electronics industry water purification

  • Food and beverage process water, subject to applicable water quality requirements

For membrane replacement projects, Clear Environment can assist with model selection based on existing membrane specifications, feed water TDS, operating pressure, and required permeate flow.

LP Series Brackish Water RO Membrane Models and Specifications

Type Membrane Model Active Area Ft(m2) Flux gpd(m3/d) Minimum Rejection Stablized Rejection Rate(%) Pressure psi(MPa) Solution NaCL(ppm) Recovery
LP
LP-4040-82
82(7.6)
2,050(7.8)
99.3
99.5
225(1.55)
2000
15
LP
LP-8040-400
400(37)
10,500(40)
99.3
99.5
225(1.55)
2000
15

Test Conditions: 1.55 MPa (225 psi), 25°C (77°F), 2000 ppm NaCl, pH 8, Recovery 15%

LP Series Membrane Performance

The LP-4040-82 and LP-8040-400 membrane elements are tested at 225 psi (1.55 MPa), 25°C, 2,000 ppm NaCl, pH 8, and 15% recovery. Both models have a stabilized salt rejection rate of 99.5%.

Actual permeate flow and salt rejection depend on feed water salinity, temperature, operating pressure, and system recovery. For feed water approaching 8,000 ppm TDS, membrane performance and operating pressure should be verified through system design calculations.

4040 & 8040 LP RO Membrane Dimensions

LP series spiral wound RO membrane element dimensional drawing

LP Series RO Membrane Element Dimensions

Dimension

LP-4040

LP-8040

Nominal diameter

4 inches

8 inches

Nominal length

40 inches

40 inches

Element diameter (D)

Approx. 99 mm

Approx. 201 mm

Nominal element length (A)

1016 mm

1016 mm

Dimensions are for reference only. Please confirm the detailed element drawing and end connection dimensions before ordering replacement membranes.

Sourcing LP Series RO Membranes from China

Clear Environment supports water treatment distributors, equipment manufacturers, and system integrators in sourcing LP series brackish water RO membrane elements from China.

We can assist with:

  • 4040 and 8040 membrane selection based on feed water TDS, operating pressure, and required permeate flow.

  • Replacement membrane sourcing, including dimensional and performance comparisons with existing elements.

  • OEM and private labeling for distributors and water treatment equipment suppliers.

  • Multi-product sourcing, including RO membrane housings and other water treatment components.

  • Order coordination and international shipping for overseas customers.

For replacement projects, please share your existing membrane model, feed water TDS, operating pressure, and required quantity so we can help identify suitable options.