XLP RO Membrane Element for Low-TDS Water Under 1000 ppm

The XLP Series RO membrane element is designed for low-salinity feedwater with TDS below 1,000 ppm. It is suitable for low-pressure reverse osmosis applications where reduced operating pressure and reliable salt rejection are important design considerations.

With a reported salt rejection of up to 99.0% under specified test conditions, the XLP Series can be considered for industrial pure water production, boiler feedwater treatment, and selected two-pass RO systems.

Clear Environment supplies XLP RO membrane elements for water treatment equipment manufacturers, system integrators, and membrane replacement projects. Contact us for model specifications, operating conditions, and quotation.

Product Features

The XLP Series RO membrane element is designed for low-TDS feedwater applications, particularly water with dissolved solids below 1,000 ppm. Its ultra-low-pressure design makes it suitable for reverse osmosis systems where operating pressure and energy consumption are important selection factors.

Key features include:

  • Ultra-low-pressure operation: Designed for low-salinity feedwater applications, subject to the membrane model’s specified operating conditions.

  • Salt rejection: Selected XLP membrane models offer salt rejection of up to 99.0% under specified test conditions.

  • Spiral-wound construction: Suitable for installation in compatible RO membrane pressure vessels.

  • Industrial water treatment applications: Can be considered for pure water production, boiler feedwater treatment, and selected two-pass RO systems.

Actual permeate flow and salt rejection depend on feedwater quality, temperature, operating pressure, and system recovery.

Maintenance and Preservation

Short-Term Shutdown

During short-term shutdowns, follow the membrane manufacturer’s flushing and preservation instructions. Flush the RO system with suitable water where required and prevent the membrane elements from drying out.

Long-Term Shutdown

For extended shutdowns, an appropriate membrane preservation procedure may be necessary to control biological growth. Sodium bisulfite solutions are commonly used for preserving compatible RO membrane elements, but the required concentration, preparation method, replacement interval, and safety precautions must follow the manufacturer’s

Applications of XLP Low-Pressure RO Membranes

XLP Series RO membrane elements are designed for low-salinity feedwater applications, particularly water with TDS below 1,000 ppm. Their ultra-low-pressure design makes them suitable for RO systems where operating pressure, permeate flow, and energy consumption are important considerations.

Typical applications include:

  • Community Water Treatment: RO systems treating suitable low-TDS groundwater or municipal feedwater.

  • Hotels and Commercial Buildings: Water purification systems for general service and process water requirements.

  • Industrial Pure Water Production: RO pretreatment and purification systems for industrial processes.

  • Boiler Feedwater Treatment: RO systems used to reduce dissolved salts before further treatment where required.

  • Food and Beverage Processing: Process water treatment systems with appropriate downstream treatment and quality monitoring.

Actual operating pressure, permeate quality, and energy consumption depend on feedwater conditions, membrane selection, and overall system design.

XLP Low-Pressure RO Membrane Models & Specifications

Type Membrane Model Active Area Ft(m2) Active Area Ft(m2) Flux gpd(m3/d) Minimum Rejection Stablized Rejection Rate(%) Pressure psi(MPa) Solution NaCL(ppm) Recovery
XLP
XLP-4040-82
82(7.6)
2,250(8.7)
98
99.0
100(0.69)
500
15
XLP
XLP-8040-400
400(37)
10,500(40)
98
99.0
100(0.69)
500
15
XLP
XLP-8040-440
440(41)
12,650(48)
98
99.0
100(0.69)
500
15

Standard Test Conditions

  • Test pressure: 100 psi (0.69 MPa)

  • Test temperature: 25°C (77°F)

  • Feed solution: 500 ppm NaCl

  • Feed pH: 8.0

  • Single-element recovery: 15%

Permeate flow and salt rejection values are based on the stated laboratory test conditions. Actual performance depends on feedwater quality, operating pressure, temperature, and system design.

XLP RO Membrane Product & Packaging Photos

XLP low-pressure RO membrane elements in 4040 and 8040 sizes
Cartons of RO membrane elements packed on pallets
Palletized RO membrane cartons prepared for shipment

Sourcing XLP Low-Pressure RO Membranes from China

  • Clear Environment supplies Chinese-brand XLP low-pressure RO membrane elements for water treatment distributors, system integrators, and engineering companies.

    Our available XLP series includes 4040 and 8040 membrane elements designed for low-salinity feedwater applications.

    How We Support Your Procurement

    • Model Selection: Help customers compare XLP membrane specifications based on feedwater TDS, operating pressure, required permeate flow, and system conditions.

    • Chinese Supplier Sourcing: Coordinate with suitable membrane suppliers according to technical requirements, quantity, and project budget.

    • OEM & Private Label: Support customized labeling and packaging where available, subject to order quantity and supplier confirmation.

    • Replacement Requirements: Assist in evaluating alternative membrane models based on dimensions, performance specifications, and operating conditions.

    • Export Coordination: Support product inspection arrangements, order consolidation, packaging, and international shipment.

    For replacement or new RO system projects, please share your existing membrane model, feedwater TDS, operating pressure, and required quantity so we can recommend suitable options.

FAQ

1. What feedwater TDS is suitable for XLP low-pressure RO membranes?

The XLP Series is designed for low-salinity feedwater, typically below 1,000 ppm TDS. Its rated performance is tested at 100 psi (0.69 MPa), 25°C, and 500 ppm NaCl. Actual operating pressure and permeate quality depend on feedwater conditions and system design.

2. Can XLP RO membranes replace other 4040 or 8040 membrane brands?

Replacement may be possible when membrane dimensions, operating pressure, permeate flow, salt rejection, and connection requirements are compatible. Please share your existing membrane model and operating conditions so we can help evaluate suitable alternatives.

3. What is the minimum order quantity for XLP RO membranes?

Standard membrane orders and OEM requirements may have different minimum quantities. Private-label options may be available from 10 pieces, depending on the model and packaging requirements. Please contact us to confirm the MOQ for your order.

4. Can you supply RO membranes with customized dimensions or private labels?

We can coordinate private-label printing, neutral packaging, and certain customized requirements with our membrane suppliers. Special dimensions or structural modifications require technical evaluation and supplier confirmation.

5. Can Clear Environment source other RO system components together with the membranes?

Yes. In addition to RO membrane elements, we can help source compatible FRP or stainless steel membrane housings, cartridge filters, pumps, pressure gauges, and other water treatment components. Multi-product sourcing and order consolidation are available for distributors and engineering companies.

RELATED PRODUCT

RELATED PRODUCT

Scroll to Top

Send your inquiry today